Rheem Furnace Pilot Light Keeps Going Out Heres the Fix

Rheem Furnace Pilot Light Keeps Going Out? Here’s the Fix

Rheem Furnace Pilot Light Won't Stay Lit? Here's the Fix

Are you having difficulty getting your Rheem furnace's pilot light to stay lit? Whether you have a natural gas, propane, or electric furnace, Rheem manufactures a wide range of furnaces for residential and commercial applications. If your pilot light won't stay lit, take some time to troubleshoot the cause of the problem before calling a professional.

Check the Settings

The first thing to check is the existing settings on the furnace. Start by checking the thermostat, ensuring that it's set to the correct temperature and type of heat (Gas, Propane, or Electric). If all is correct, you'll then need to check the pilot light. For natural gas and propane furnace units, the pilot light should be set to "Low", although some models have a "High" setting. For electric furnaces, make sure the power switch is on. Another good troubleshooting step is to ensure that the pilot light is seated firmly in the igniter hole and not blocking the hole.

Clear the Port

The second step is to check the pilot light port for debris. If the port is blocked with lint or dust, the pilot light won't be able to stay lit. If the port is blocked, gently clean it out with a cloth and vacuum. Once it's clear again, your pilot light should be able to stay lit.

Check the Gas Connection

For natural gas and propane furnaces, you'll need to check the gas connection to make sure it's working properly. The connection should be firmly attached and free of obstructions. If it's not, the flame won’t be able to stay lit. Make sure the connection is in good condition and that the pilot light is properly aligned. You may want to try tightening the connection to make sure it’s secure.

Adjust the Flame

In some cases, the problem can be with the flame itself. If the flame is too hot or too low, it might not be the right size or heat to stay lit. While it may work temporarily, the pilot light will eventually shut off if it's not the correct size or intensity. Before doing anything else, adjust the pilot light flame to a lower setting and then try turning it on again.

Call an Expert

In some cases, no matter how much troubleshooting you do, the pilot light won't stay lit. If this is the case, it's best to call a professional to determine the cause of the problem. A technician can diagnose the issue and recommend a solution. At Local Reliable Appliance Repair, our highly-trained technicians have the experience necessary to diagnose and repair any Rheem furnace problem. We have been serving the San Diego area for more than 20 years, providing high-quality repairs and hassle-free maintenance. If you wish to read more information about Rheem Furnace Pilot Light Won't Stay Lit, please click here. When you need reliable service and repair for your Rheem furnace, call Local Reliable Appliance Repair at (866) 516-1222.

Rheem Furnace Pilot Light Keeps Going Out? Here's the Fix
Rheem Furnace Pilot Light Keeps Going Out? Here's the Fix
Rheem Furnace Pilot Light Keeps Going Out? Here's the Fix

Rheem Furnace Pilot Light Won't Stay Lit

Manufacturers and local technicians recommend a number of preventive actions to avoid issues with Rheem furnace pilot light won't stay lit. Below is an itemized list of the most important preventative measures for this issue:

1) Check the Thermocouple

The thermostat usually requires replacing when the pilot light is continuously going on and off. A faulty thermocouple won't detect changes in temperatures, resulting in an incorrectly set flame which could cause the pilot light to go off. Replacing the thermostat should resolve this issue.

2) Check Gas Pressure

An inadequate gas pressure will cause the pilot light to go off. The gas pressure must match the furnace's specifications. It is important to check the gas pressure to ensure it is within the permitted limits.

3) Clean Any Debris

Debris can clog up the air intake or the chimney, resulting in insufficient fuel supply for the pilot light. Regularly cleaning the furnace and its surrounding areas will reduce the risk of the pilot light going off from blockages.

4) Replace Old Components

The components within the furnace can wear out over time, resulting in the pilot light failing to stay lit. Thus, it is important to replace any faulty, worn-out parts before they start causing issues.

By following these preventive measures for Rheem furnace pilot light won't stay lit, furnace owners can reduce the risk of the light going out and make sure the furnace is running properly at all times.

Repair Costs for a "Rheem Furnace Pilot Light Won't Stay Lit" Issue in San Diego

Finding repairs or installation for a broken Rheem furnace in San Diego can be intimidating, as the cost for parts and labor can be high. However, it doesn’t have to be an expensive or time-consuming process. Call Local Reliable Appliance Repair at tel:(866) 516-1222 for expert advice and a free quote.

The Rheem Furnace Pilot Light issue can be caused by several variables. The starting cost of repairs or replacements may be lower if a few changes are made in the home. Smaller repairs are typically less expensive, and may include cleaning the thermocouple, changing the battery in the circuit board, or replacing bad wiring in the pilot operatory.

The cost for parts can range according to the requirements for the repairs. Most replacements require a furnace or an igniter, a new spark module, a thermocouple, or a wall switch. Parts that may be necessary include:

  • Igniter: $20 – $250
  • Thermostat: $50 – $200
  • Wall switch: $30 – $150
  • Relays: $30 – $75
  • Spark module: $45 – $125
  • Circuit board: $50 – $400

Repairs can also involve labor costs, which vary based on the work needed. For a minor issue, the cost of labor may be up to $150, while more complex repairs, including part replacement and considerable labor, start at around $250 and can go up to $1,000. Of course, the cost of each job differs depending on the problem and how quickly a fix is needed.

The best way to get the repair process started is to consult a reliable technician. Local Reliable Appliance Repair can save you time and money by providing expert repairs, emergency service, and accurate estimates. Call them at tel:(866) 516-1222 for a free quote and quality service.

Rheem Furnace Pilot Light Won't Stay Lit

Running a Rheem furnace, but your pilot light won’t stay lit? The professionals at Reliable Appliance Repair (866) 516-1222 are your best bet to get the job done right.

Reliable is a trusted local HVAC and appliance repair company based in San Diego. As a family-owned business, they understand the importance of same-day service and will dispatch an experienced technician to your location in record time. Plus, they offer $25 off labor for new customers.

Reliable’s technicians are highly trained and have a minimum of 5 years of on-site experience. They specialize in repairing Rheem furnaces, so you can feel confident knowing that the job will be done correctly. They also offer fair and affordable pricing for all their services.

Reliable is also licensed and insured, so you can rest easy knowing that you’re in good hands. So, if your Rheem furnace’s pilot light won’t stay lit, don’t worry—help is just a phone call away. Reach out to the knowledgeable professionals at Reliable Appliance Repair at (866) 516-1222 and get back to enjoying the comfort of your home in no time.

FAQ: Troubleshooting Rheem Furnace Pilot Light

Why does my Rheem furnace pilot light keep going out?

Troubleshooting a pilot light that keeps going out could be caused by the air filter being too dirty, the power switch being off or the thermocouple being defective.

How can I fix my Rheem furnace pilot light that won't stay lit?

Check the power switch is on, clean the air filter, if it's still not working, the thermocouple may need to be replaced by a professional.

How often should I clean the air filter on my Rheem furnace?

Monthly is recommended to keep the air filter clean and free from dirt and grime.

What is a thermocouple and why could it be the cause of my pilot light going out?

The thermocouple is a safety device that shuts off the gas if the pilot light goes out. If the thermocouple needs to be replaced it should be done so by a professional.

If your Rheem furnace pilot light continues to keep going out or won't stay lit, please contact a Local Reliable Appliance Repair at tel:(866) 516-1222 for assistance.